0113 248 9966
0113 248 9966
Booking and info

Fluke 6500-2 Kits (Choice of Kits)

  • A comprehensive PAT tester with options for RCD and load & run testing
  • Downloadable memory complemented by different software packages
  • Choice to add a PAT label printer and barcode scanner for more efficient testing

Choose kit *

Optional Extras

£1,099.00+VAT
In stock
+

Description

The Fluke 6500-2 PAT Tester is a sophisticated appliance tester that can perform earth bond tests, insulation tests, leakage current tests, load & run testing, portable RCD testing (current & trip time) and polarity checking. These capabilities make the tester suitable for use on Class I and Class II appliances as well as extension leads.

Clearly-labelled buttons mean that the Fluke 6500-2 is very easy to use. It has automated test sequences for different appliance types and is also capable of manual testing. Test readings and PASS/FAIL indications are shown on the backlit digital screen and these results are also saved to the PAT tester’s internal memory (max. 1000 results). It is possible to transfer data to a PC and there is a full QWERTY keyboard for swift data entry.

The Fluke 6500-2 comes in five different kits which feature a range of useful accessories. These include PAT adaptors for 110V appliances and extension leads, different software packages, a socket tester, and a microwave leakage detector. Furthermore, there are options for a barcode scanner and/or Fluke SP6000 PAT label printer.

Kit Contents

Kit A Kit B Kit C Kit D Starter Kit
Fluke 6500-2 PAT Tester
SimplyPATs Version 7 Software
Fluke 0702/PAT Software
Barcode Scanner
Fluke SP6000 Mini Printer
Barcode ID Labels
Fluke 110V Adaptor Kit
IEC Adaptor Kit, 110V & 230V Extension Lead Adapter
EXTL100 Extension Lead Adaptor
1000 Pass Labels, 200 Fail Labels & 250 PassWrap Labels
Pass 560R Labels
Microwave Leakage Detector & Microwave Emission Labels
TEK989 Socket Tester

 

Fluke 6500-2 PAT Testing Kit A Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adaptor
  • 230V Extension Lead Adaptor
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Testing Kit B Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • SimplyPATs Version 7
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adapter
  • 230V Extension Lead Adapter
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Testing Kit C Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • SimplyPATs Version 7
  • Barcode Scanner
  • Barcode ID Labels
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adapter
  • 230V Extension Lead Adapter
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Testing Kit D Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • SimplyPATs Version 7
  • Barcode Scanner
  • Fluke SP6000 Mini Printer
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adapter
  • 230V Extension Lead Adapter
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Starter Kit Includes:

  • Fluke 6500-2 PAT Tester
  • Instructions for Fluke 6500-2 PAT Tester
  • Test leads
  • Test probes
  • Crocodile clips
  • Mains cord
  • Storage case
  • USB stick
  • USB cable
  • EXTL100 Extension Lead Adaptor
  • Fluke 0702/PAT Software
  • Sheet of PASS 560R

Specification

Power-on Test

  • The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
  • Display Range : 90 V to 264 V
  • Accuracy at 50 Hz: ± (2% + 3 counts)
  • Resolution: 0.1 V
  • Input Impedance: > 1 MΩ // 2.2 nF
  • Maximum Input Mains Voltage: 264 V

Earth Bond Test (Rpe)

  • Display Range: 0 to 19.99 Ω
  • Accuracy (After Bond Test Zeroing): ± (5% + 4 counts)
  • Resolution: 0.01 Ω
  • Test Current: 200 mA AC -0% +40% into 1.99 Ω; 25 A AC ± 20% into 25 mΩ at 230 V
  • Open Circuit Voltage: > 4 V AC, < 24 V AC
  • Bond Test Zeroing: Can subtract up to 1.99 Ω

Insulation Test (Riso)

  • Display Range: 0 to 299 MΩ
  • Accuracy: ± (5% + 2 counts) from 0.1 to 300 MΩ
  • Resolution: 0.01 MΩ (0 to 19.99 MΩ) / 0.1 MΩ (20 to 199.9 MΩ) / 1 MΩ (200 to 299 MΩ)
  • Test Voltage: 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0 % +25 % at 250 kΩ load
  • Test Current: > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
  • Auto Discharge Time: < 0.5 s for 1 μF
  • Max. Capacitive Load: Operational up to 1 μF

Touch Current Test

  • Display Range: 0 to 1.99 mA AC
  • Accuracy: ± (4% + 2 counts)
  • Resolution: 0.01 mA
  • Internal Resistance (via Probe): 2 kΩ
  • Measuring Method: Probe*

Substitute Leakage Current Test

  • Display Range: 0 to 19.99 mA AC
  • Accuracy: ± (2.5% + 3 counts)
  • Resolution: 0.01 mA
  • Test Voltage: 100 V AC ± 20%

Load/Leakage Test: Load Current

  • Display Range: 0 A to 13 A
  • Accuracy: ± (4% + 2 counts)
  • Resolution: 0.1 A*

Load/Leakage Test: Load Power

  • Display Range 230 V Mains: 0.0 VA to 3.2 kVA
  • Accuracy: ± (5 % + 3 counts)
  • Resolution: 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*

Load/Leakage Test: Leakage Current

  • Display Range: 0 to 19.99 mA
  • Accuracy: ± (4% + 4 counts)
  • Resolution: 0.01 mA*

PELV Test

  • Accuracy at 50 Hz: ± (2% + 3 counts)
  • Overload Protection: 300 V rms
  • Warning Threshold: 25 V rms

RCD Test: Trip Current

  • Operational Error: ±10 %
  • Nominal: 30 mA
  • Accuracy: ±5 %

RCD Test: Trip Time

  • Standard Requirement: 61557 Part 6; tolerance of rated test current 0 % to +10 %
  • Operational Error: ±10 %
  • RCD Type: AC general-purpose 30 mA
  • Display Range: 310 ms
  • Resolution: 0.1 ms
  • Accuracy: 3 ms
  • Trip Time Limit at 100 % (30 mA): 300 ms
  • Trip Time Limit at 500 % (150 mA): 40 ms

*The appliance under test is energised at mains voltage.

Environmental

  • Operating Temperature: 0 to 40 °C
  • Relative Humidity: Non condensing < 10 °C / 95% from 10 to 30 °C / 75% from 30 to 40 °C

Safety

  • Safety Rating: Complies with EN61010-1 3rd edition / CAT II, 300 V, pol 2

General

  • Size: 200 mm (L) x 275 mm (W) x 114 mm (H)
  • Weight: 3.13 kg
  • Power Supply: 230 V +10 % -15 %, 50 Hz ±2 Hz or (6500-2 only: 110V +10 % -15 %,50 Hz ±2 Hz)
  • Power Consumption (Tester): 13 W typical (idle) / 60 W max. during 25A Bond test
  • Storage Temperature: -10 to 60 °C
  • Corrosion: 70 °C @ 95 % RH for 5 days max.
  • Operating Altitude: 0 up to 2000 m
  • Sealing: IP-40 (enclosure), IP-20 (connectors)
  • EMC: Complies with EN61326-1, portable
  • EMI Immunity: 3 V/m

Supplied Accessories

Fluke 6500-2 PAT Testing Kit A Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adaptor
  • 230V Extension Lead Adaptor
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Testing Kit B Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • SimplyPATs Version 7 1
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adapter
  • 230V Extension Lead Adapter
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Testing Kit C Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • SimplyPATs Version 7 1
  • Barcode Scanner 2
  • Barcode ID Labels
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adapter
  • 230V Extension Lead Adapter
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Testing Kit D Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • SimplyPATs Version 7 1
  • Barcode Scanner 2
  • Fluke SP6000 Mini Printer 3
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adapter
  • 230V Extension Lead Adapter
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

Fluke 6500-2 PAT Starter Kit Includes:

  • Fluke 6500-2 PAT Tester
  • Instructions for Fluke 6500-2 PAT Tester
  • Test leads
  • Test probes
  • Crocodile clips
  • Mains cord
  • Storage case
  • USB stick
  • USB cable
  • EXTL100 Extension Lead Adaptor
  • Fluke 0702/PAT Software
  • Sheet of PASS 560R