  • A tester with multiple PAT features and an internal memory for 10,000 results
  • All kits feature 110V appliance and extension lead adaptors, labels and IEC adaptors
  • Add software packages, a barcode scanner, a PAT label printer, or a microwave leakage detector

Choose kit *

Optional Extras

£1,009.00+VAT
In stock
FREE delivery
+

Product videos

Description

The Megger PAT410 PAT Tester is suitable for high-volume PAT testing in domestic and commercial environments thanks to its large internal memory which has space for up to 10,000 result sets. It can perform a 200mA earth bond test, 250V/500V insulation tests, substitute/differential/touch leakage current measurement, load & run testing, polarity checking, fuse testing and portable RCD testing.

The Megger PAT410 has automatic sequences for testing Class I/Class II appliances and IEC/extension leads and can display numerical test results and a PASS/FAIL indication on its clear colour screen. Results saved to the internal memory are fully downloadable to a PC using the integrated USB port. The tester also has a QWERTY keypad which allows the user to add notes to saved records whilst five hot keys initiate the most frequently-used tests.

A range of kits offer plenty of choice for the Megger PAT410. Every kit features PAT labels, IEC adaptors, and 110V adaptors which allow testing on industrial appliances and extension leads. Additionally, the user can choose to add a Megger PAT400 label printer, one of two software packages (Lite or Contractor), a barcode scanner, or a microwave leakage detector. A full summary of all five kits is available below.

Kit Contents

Kit A Kit B Kit C Kit D Kit E
Megger PAT410
Megger Powersuite Pro Lite PAT Software
Megger Powersuite Professional Contractor PAT Software
Megger PAT Label Printer
2 x Megger PAT Label Cartridges
Megger Barcode Scanner
Microwave Leakage Detector
150 Microwave Emission Labels
IEC Clover Leaf Adapter
IEC PAT Adaptor Kit
110V Appliance Adaptor
110V Extension Lead Adaptor
Pass Labels 1000 500 1000 1000 1000
Fail Labels 400 200 400 400 400
PassWrap Cable Labels 250 250 250 250
230V Extension Lead Adaptor
Calibration Certificate
PAT410 Carry Case

 

Megger PAT410 PAT Testing Kit A Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT410 PAT Testing Kit B Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 500 Pass Labels
  • 200 Fail Labels

Megger PAT410 PAT Testing Kit C Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT410 PAT Testing Kit D Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT410 PAT Testing Kit E Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Specification

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 – 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK
  • Supply range: 230V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 145 x 255 x 320mm
  • Weight: 2.7kg

Supplied Accessories

Megger PAT410 PAT Testing Kit A Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT410 PAT Testing Kit B Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 500 Pass Labels
  • 200 Fail Labels

Megger PAT410 PAT Testing Kit C Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT410 PAT Testing Kit D Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT410 PAT Testing Kit E Includes:

  • Megger PAT410 PAT Tester (complete with Earth Bond Test Lead, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, PAT410 Instruction Manual, Calibration Certificate and Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels