0113 248 9966
0113 248 9966
Booking and info

Megger PAT450 Kits (Choice of Kits)

Megger Official Distributor
  • An advanced appliance tester with a large internal memory and flash testing function
  • All kits feature IEC and 110V extension lead adaptors, PAT labels and a carry case
  • Add a PAT label printer, barcode scanner, and one of two professional software packages

Choose kit *

Optional Extras

£1,199.00+VAT
In stock
+

Product videos

Description

The Megger PAT450 PAT Tester is powerful appliance tester with multiple features that make it suitable for use in residential, commercial and industrial settings. It can perform earth bond continuity testing (200mA, 10A, 25A), insulation resistance testing (250V, 500V), substitute/differential/touch leakage measurement, load & run testing, polarity checking, portable RCD testing and fuse testing. Furthermore, there is a flash testing function (1.5kV, 3kV) that is ideal for use in repair centres and production facilities. An inbuilt 110V test socket means that there is no need for an adaptor in order to test power tools and other appliances.

Numerical results and a PASS/FAIL indication are shown on the illuminated colour display and limits can be adjusted by the user. Up to 10,000 data sets can be saved to the Megger PAT450’s internal memory and these are downloadable via the USB port. A full QWERTY keyboard can be used to add details and notes to records whilst five hot keys initiate the most common tests and there are also automatic sequences for Class I appliances, Class II appliances and extension leads as well as a manual mode.

The Megger PAT450 is available in a range of kits that enable the user to make the most of the advanced testing capabilities. Each kit contains a carry case, IEC adaptors, extension leads, and PAT labels. It is possible to add a Megger PAT400 Label Printer, a barcode scanner, microwave leakage detector, Megger Powersuite Lite software or a Megger Powersuite Contractor software according to the user’s preferences.

Kit Contents

Kit A Kit B Kit C Kit D Kit E
Megger PAT450 Tester
Megger Powersuite Pro Lite PAT Software
Megger Powersuite Professional Contractor PAT Software
Megger PAT Label Printer
Megger PAT Label Cartridges 2 2 2
Megger Barcode Scanner
Microwave Leakage Detector
150 Microwave Emissions Labels
IEC Clover Leaf Adaptor
IEC PAT Adaptor Kit
110V Extension Lead Adaptor
Pass Labels 1000 500 1000 1000 1000
Fail Labels 400 200 400 400 400
250 PassWrap Cable Labels
Earth Bond Test Lead
230V Extension Lead Adaptor
Calibration Certificate
PAT450 Carry Case

 

Megger PAT450 Tester Kit A Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT450 Tester Kit B Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 500 Pass Labels
  • 200 Fail Labels

Megger PAT450 Tester Kit C Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT450 Tester Kit D Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT450 Tester Kit E Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Specification

Earth Bond test (10A and 25A)

  • Open circuit voltage: 9V AC (Supply 230V)
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (0 to 1.99 Ω)
  • Display range: 0 to 1.99 Ω

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 – 99 VA), ±5% ±50 digits (100 VA – 999 VA), ±5% ±100 digits (1000 VA – 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK

Flash test

  • Voltage: 1500V AC for Class 1, 3000V AC for Class2
  • Current: <3.5 mA short circuit @ 253 V
  • Breakdown current accuracy: ±5% ±5 digits
  • Breakdown current resolution: 0.01mA
  • Display range: 0 to 3mA
  • Supply range: 230V at 50Hz, 110V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 180 x 255 x 320mm
  • Weight: 5kg

Supplied Accessories

Megger PAT450 Tester Kit A Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT450 Tester Kit B Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 500 Pass Labels
  • 200 Fail Labels

Megger PAT450 Tester Kit C Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT450 Tester Kit D Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Pro Lite PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels

Megger PAT450 Tester Kit E Includes:

  • Megger PAT450 PAT Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Clover Leaf Adaptor, Flash Test Probe, PAT450 Instruction Manual, Calibration Certificate & Carry Case).
  • Megger Powersuite Professional Contractor PAT Software
  • Megger PAT Label Printer
  • 2 x Megger PAT Label Cartridges
  • Megger Barcode Scanner
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • 1000 Pass Labels
  • 400 Fail Labels
  • 250 PassWrap Cable Labels