0113 248 9966
0113 248 9966
Booking and info

Metrel A1322 Active 3-Phase Adaptor

Metrel Official Distributor
  • Permits a comprehensive range of tests on three-phase appliances and extension leads
  • Compatible with Metrel PAT testers including the SigmaPAT and DeltaPAT
  • A range of inbuilt sockets allows testing of a wide array of three-phase equipment
£2,142.00+VAT
In stock
+

Description

The Metrel A1332 Active 3-Phase Adaptor allows troubleshooting and testing on three-phase appliances and machinery. It can perform tests such as active polarity checking, differential leakage measurement and three-phase RCD testing so is ideal for advanced testing. It is compatible with Metrel SigmaPAT and DeltaPAT testers and permits functional tests on machinery up to 40A. Multiple test sockets make the adaptor suitable for a range of different appliances and leads, including RCD-protected extension leads.

Key Features

  • Comprehensive testing on 3-phase electrical equipment
  • 3-phase live leakage
  • 3-phase differential leakage
  • Insulation resistance
  • 3-phase power testing (kVA, kW, kVAr & Cos)
  • RCD (3-Phase P/RCD Testing) Type (AC,A,B, PRCD-S & P/RCD-K)
  • Simple connection to the PAT tester with automatic detection
  • Simple test procedures, identical to single phase equipment
  • Built-in CEE 3-PH/32A 5 pin, CEE 3-PH/16A 5 pin and CEE 1-PH/16A 3 pin test sockets
  • Robust waterproof case

Specification

Differential leakage current (230/400 VAC or 120/208 VAC)

  • Differential leakage current accuracy: 0.00 mA ÷ 9.99 mA 0.01 mA ±(5 % of reading + 5 digits)
  • Power / Functional test (230/400 VAC or 120/208 VAC)
  • Apparent power accuracy: 0.00 kVA ÷ 24.29 kVA 0.01 kVA ±(5 % of reading + 5 digits)
  • Active power readout Range Resolution Accuracy 0.00 kW ÷ 24.29 kW 0.01 kW ±(5 % of reading + 5 digits)
  • Reactive power readout Accuracy 0.00 kW ÷ 24.29 kVAr 0.01 kVAr ±(5 % of reading + 5 digits)
  • Power factor readout Range Resolution Accuracy 0.00 ÷ 1.00 0.01 ±(5 % of reading + 5 digits)
  • 3-phase RCD / Test current (10 mA, 15 mA, 30 mA, 100 mA, 300 mA)
  • Portable RCD trip-out time readout (AC and A type PRCD)
  • Range Resolution Accuracy
  • 0 ms ÷ 300 ms (½ x IΔN, IΔN ) 1 ms
  • 0 ms ÷ 150 ms (2 x IΔN) 1 ms ±3 ms
  • 0 ms ÷ 40 ms (5 x IΔN) 1 ms
  • Portable RCD trip-out current readout (B type PRCD)
  • Range Resolution Accuracy
  • 0.2 x IΔN ÷ 2.2 x IΔN 0.05 x IΔN ±0.1 x IΔN
  • Polarity test Standard test (<60 VAC and DC)
  • Polarity test Active (Mains supply voltage, over-current protection)

General data

  • Supply voltage single-phase 230 V ±10 %
  • Supply voltage 3-phase 230/400 V ±10 %
  • 120/208 V ±10 %
  • Maximum test current 32 A, 40 A max (10 min)
  • Overvoltage category 300 V/CAT II
  • Protection classification I
  • Pollution degree 2
  • Protection degree IP 65 (closed and locked cover) / IP 20 (connectors)
  • Case Shock proof plastic, portable
  • Dimensions: 335 mm x 160 mm x 335 mm
  • Weight (without accessories) 7.2 kg