0113 248 9966
0113 248 9966
Booking and info

Metrel A1422 Three-Phase and Welding Equipment Adaptor

Metrel Official Distributor
  • Enables electrical safety testing on three-phase appliances and ARC welding units
  • A range of inbuilt sockets for different appliances and extension leads
  • Performs three-phase RCD testing, differential leakage measurement, no-load voltage and more
£1,495.00+VAT
In stock
+

Description

The Metrel A1422 Three-Phase and Welding Equipment Adaptor is compatible with a range of Metrel PAT testers and enables safety testing on three-phase appliances and ARC welding units. There are multiple sockets including CEE three-phase to 16A 5-pin, 32A 5-pin and 16A 3-pin which allows it to perform active polarity testing, differential leakage measurement and three-phase RCD testing on a range of instruments. It will work with a maximum current of 40A.

Various tests such as open-circuit voltage testing, circuit leakage measurement, no-load voltage testing and insulation testing can be carried out on ARC welding units using the Metrel A1422. A durable waterproof case helps protect from water and dust ingress.

Key Features

  • Suitable for use with MI3321, MI3310 and MI3360
  • Three-phase appliance testing up to 40A
  • Numerous sockets for extension lead testing
  • Three-phase RCD testing function
  • Open circuit voltage test on arc welding units
  • Welding equipment tests (EN60974-4)
  • Automatic recognition of supporting tester
  • Internal memory stores test sequences and results

Specification

Differential leakage current (230/400 VAC or 120/208 VAC)
Differential leakage current readout

  • Range: 0.00 mA ÷ 9.99 mA 
  • Resolution: 0.01 mA 
  • Accuracy: ±(5 % of reading + 5 digits)
  • Power / Functional test (230/400 VAC or 120/208 VAC)

Apparent power readout

  • Range: 0.00 kVA ÷ 24.00 kVA 
  • Resolution: 0.01 kVA 
  • Accuracy: ±(5 % of reading + 5 digits)

Active power readout

  • Range: 0.00 kW ÷ 24.00 kW 
  • Resolution: 0.01 kW 
  • Accuracy: ±(5 % of reading + 5 digits)

Reactive power readout

  • Range: 0.00 kW ÷ 24.00 kVAr 
  • Resolution: 0.01 kVAr 
  • Accuracy: ±(5 % of reading + 5 digits)

Power factor readout

  • Range: 0.00 ÷ 1.00 
  • Resolution: 0.01 
  • Accuracy: ±(5 % of reading + 5 digits)

3-phase RCD / Test current (10 mA, 15 mA, 30 mA, 100 mA, 300 mA)

Portable RCD trip-out time readout (AC and A type PRCD)

  • Range: 0 ms ÷ 300 ms (½ x I∆N, I∆N) / 0 ms ÷ 150 ms (2 x I∆N) / 0 ms ÷ 40 ms (5 x I∆N)
  • Resolution: 1 ms / 1 ms / 1 ms 
  • Accuracy: ±3 ms

Portable RCD trip-out current readout (B type PRCD)

  • Range: 0.2 x I∆N ÷ 2.2 x I∆N 
  • Resolution: 0.05 x I∆N 
  • Accuracy: ±0.1 x I∆N

Continuity of the protective circuit (according to IEC/ EN 60974-4)

Test current set to 10 A

  • Range: 0.00 Ω ÷ 1.99 Ω / 2.00 Ω ÷ 19.99 Ω 
  • Resolution: 0.01 Ω / 0.01 Ω
  • Accuracy: ±(5 % of reading + 3 digits) / ±10 %

Test current set to 200 mA

  • Range: 0.00 Ω ÷ 1.99 Ω / 2.00 Ω ÷ 9.99 Ω / 10.0 Ω ÷ 19.9
  • Resolution: 0.01 Ω / 0.01 Ω / 0.1 Ω
  • Accuracy: ±(5 % of reading + 3 digits) / ±10 %

Insulation resistance (supply circuit to protective circuit); (welding circuit to protective circuit); (Insulation resistance supply circuit to welding circuit; (according to IEC/ EN 60974-4)

Insulation LN-PE readout; W-PE readout; LN-W readout:

  • Range: 0.000 MΩ ÷ 0.500 MΩ / 0.501 MΩ ÷ 1.999 MΩ / 2.00 MΩ ÷ 19.99 MΩ / 20.0 MΩ ÷ 199.9 MΩ 
  • Resolution: 0.001 MΩ / 0.001 MΩ / 0.01 MΩ / 0.1 MΩ 
  • Accuracy: ±(10 % of reading + 5 digits) / ±(5 % of reading + 3 digits)

Insulation resistance (supply circuit of class II equipment to accessible surfaces) (according to IEC/ EN 60974-4)

Insulation LN-P readout:

  • Range: 0.000 MΩ ÷ 0.500 MΩ / 0.501 MΩ ÷ 1.999 MΩ / 2.00 MΩ ÷ 19.99 MΩ
  • Resolution: 0.001 MΩ / 0.001 MΩ / 0.01 MΩ
  • Accuracy: ±(10 % of reading + 5 digits) / ±(5 % of reading + 3 digits)

Welding circuit leakage current; Primary leakage current (according to IEC/ EN 60974-4)

Welding circuit leakage current readout; Primary leakage current readout:

  • Range: 0.00 mA ÷ 14.99 mA 
  • Resolution: 0.01 mA 
  • Accuracy: ±(5 % of reading + 5 digits)

No load voltage (acc. to IEC/ EN 60974-4)

No load voltage readout: (AC peak or DC peak)

  • Range: 0.0 V ÷ 199.9 V 
  • Resolution: 0.1 V 
  • Accuracy: ±(5 % of reading + 5 digits)

No load voltage readout: (AC RMS)

  • Range: 0.0 V ÷ 139.9 V 
  • Resolution: 0.1 V 
  • Accuracy: ±(5 % of reading + 5 digits)
  • Polarity test Standard test (<60 VAC and DC)
  • Polarity test Active (Mains supply voltage, over-current protection)

Supplied Accessories

The Metrel A1422 comes with:

  • Metrel A 1422 Three-Phase and Welding Equipment Adaptor
  • Bag for accessories
  • Measuring / Connection cable between Adapter and Instrument
  • 3-phase mains cable 16 A male / 32 A female, 5-pin, 2 m
  • RS232 cable
  • Instruction manual, short instruction manual
  • Calibration certificate