0113 248 9966
0113 248 9966
Booking and info

Seaward Apollo 500+ PAT Tester

Seaward Official Distributor
  • Large internal memory for up to 10,000 results, ideal for high-volume testing
  • 200mA earth bond test, insulation resistance test, RCD testing
  • Capable of producing QR codes with optional printer

Free gift

Includes: 110V adaptor, 500 PASS labels, 200 FAIL labels, 250 Passwrap labels, an IEC cloverleaf adaptor and a PAT register book.

Optional Extras

£1,171.00+VAT
In stock
+

Free gift with this product

Seaward PAT Accessory Bundle
Seaward PAT Accessory Bundle 1
Worth £85.00

Includes: 110V adaptor, 500 PASS labels, 200 FAIL labels, 250 Passwrap labels, an IEC cloverleaf adaptor and a PAT register book.

Description

The Seaward Apollo 500+ PAT Tester is a high-spec PAT tester that combines sophisticated testing features with a large internal memory and intuitive operation. It can test appliances with a 200mA earth bond test, 250V/500V insulation tests, load and run test, touch/alternative leakage current measurement, and polarity checking. These capabilities make the tester suitable for the comprehensive testing of Class I and Class II appliances as well as extension leads. There are also RCD and power socket testing functions.

One of the main features of the Seaward Apollo 500+ is its risk-based assessment tool which calculates an appropriate retest date based on official criteria. Operating the tester is extremely easy thanks to the improved interface and database search function. The instrument has a full QWERTY keyboard — ideal for appliance data entry — as well as clear navigation buttons which help select the test function using the menus on the clear colour display.

A large internal memory has enough space for up to 10,000 test results which makes the Seaward Apollo 500+ ideal for high-volume testing. It is possible to download results wirelessly via Bluetooth or via the USB port and it is compatible with optional Seaward PATGuard 3 software which is a great tool for analysis and reporting.

The Seaward Apollo 500+ can work with an optional Seaward Test n Tag Elite 2 Printer to produce customised PAT labels with a company logo, test result, appliance ID and even a 2D QR code. This allows the end user to scan the label and access all the test information using their smartphone. A Seaward QR and Barcode Scanner can also be purchased separately to enable the tester to instantly read appliance information from previous labels and QR codes.

Key Features

  • Multiple testing functions
  • Touch/alternative leakage current
  • Portable RCD testing
  • Risk calculator for next test date
  • Full QWERTY keyboard
  • Memory storage for 10,000 results
  • Bluetooth and USB connectivity
  • Capable of producing QR-coded PAT labels
  • Great for high-volume testing
Apollo 400+ Apollo 500+ Apollo 600+
Battery & mains powered
Colour Screen & QWERTY keypad
Large internal memory 2000 records 10,000 records 50,000 records + 2000 images
Scanner & printer compatible
Password controlled user accounts
Clone facility to set up multiple testers
Checkbox supplied as standard
Comprehensive electrical safety test features
Point to point measurement (Rpe & IR) ✔ (Optional Accessory Required)
User configurable electrical test/visual inspection sequences 25 100 100
User set sites & locations 50 50 100
Risk based retest period calculator
User definable comments lines against test records
Configurable checklists for any workplace test or inspection (user tests)
On-board camera
Universal risk assessment
Health & safety certificates
Bluetooth connectivity
Remote data transfer via mobile device ✔ (Android Only) ✔ (Android Only) ✔ (Android & iOS)
Download to PC via USB cable
Upload previous results to tester for retest
Data transfer via USB flash drive

Specification

Earth Continuity

  • Test Current: +/- 200mA DC
  • Display Range: 0.01 – 19.99Ω
  • Pass Value: User Defined

Insulation Resistance

  • Test Voltage: 500V / 250V DC @ 1mA nominal
  • Display Range: 0.01MΩ – 19.99MΩ
  • Pass Value: User Defined

IEC Lead Test

  • Test voltage: 5V ac nominal
  • Test: Live / Neutral Checks for o/c, s/c and crossed

Protective Conductor Current/Load

  • Test Voltage: Supply voltage, maximum load current 16A
  • Display Ranges: 0.01mA to 19.99mA
  • Pass Value: User Defined

Touch Current

  • Test Voltage: Supply Voltage, maximum load current 16A
  • Display Range: 0.00 – 3.50mA
  • Pass Value: User defined

Load Power/Current

  • Test Voltage: Supply Voltage, maximum load current 16A
  • Test Duration: Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
  • Display Range: 0.00kVA – 4.00kVA 0.00A – 16.00A

Alternative Leakage Current

  • Test Voltages: >25Vac <50Vac
  • Display Range: 0.00mA to 19.99mA
  • Pass Value: User Defined

RCD Test

  • Test Voltage: 230V +10%,-15%
  • Test Current: 30mA / 150mA rms sinusoidal
  • Display Range: 0ms – 2000ms (30mA), 0-40ms (150mA)
  • Test method: Internal isolation to avoid tripping distribution board RCD

Power Socket Test

  • Voltage Range: 207V – 253V AC Indicates configuration of voltage potential:- Line potential phase to earth, Line potential phase to neutral, Line potential neutral to earth

General

  • Memory size 10,000 records
  • Weight 1.5kg
  • Dimensions 230mm x 150mm x 100mm
  • Power Source Mains or Rechargeable battery pack

Supplied Accessories

The Seaward Apollo 500 PAT Tester comes with:

  • Apollo Calibration Checkbox
  • UKAS Calibration Certificate
  • 2 Year Warranty (requires product registration)
  • Quick Start Guide
  • 30 Day Free Trial of PATGuard 3 Software
  • Mains Power Lead
  • 2 x Test Leads with Probes/Croc Clips
  • 0.5m IEC Lead
  • USB Download Cable
  • Carry Case