The Seaward Primetest 250+ PAT Tester boasts a range of advanced testing options alongside an internal memory and data transfer facility. It has a compact, battery-powered design with simple operation and a clear digital screen.

The Seaward Primetest 250+ can perform an earth continuity test, 250V/500V insulation test, polarity checking, leakage/touch current measurement, earth leakage current measurement, and 30mA RCD trip time testing. With an adaptor, the tester can even be used on three-phase equipment found in commercial environments.

An internal memory with space for up to 999 results means that the Seaward Primetest 250+ can save the results of a day’s testing so there is no need to manually record activity. The records can then be downloaded in a CSV format with the supplied USB cable. The tester is compatible with Seaward PATGuard 3 Elite software which enables storage of data and creation of PAT certificates and reports.

The Seaward Primetest 250+ can be used in conjunction with an optional Seaward Test n Tag Pro printer which allows the user to print customised PAT labels. It comes supplied with an extension lead adaptor, earth lead, mains lead and carry case.

Key Features

  • Simple user-friendly operation
  • Portable, battery-powered device
  • Internal memory for 999 readings
  • 250V/500V insulation testing
  • Polarity checking
  • 30mA RCD trip time test
  • Three-phase appliance test
  • Earth continuity test
  • Data download in CSV format

 

Primetest 50 Primetest 100 Primetest 250 Primetest 250 Plus
Earth Continuity Test
Insulation Test (250V)
Insulation Test (500V)
Polarity Test
Leakage Current Test
Touch Current Test
Protective Conductor Current Test
RCD Trip Time Test
PASS/FAIL Indication
Numeric Reading Values
Extension Lead Test
Socket Test
Three-Phase Testing
Auto Test Sequences
Internal Memory (999 results)
Compatible with Seaward TNT Pro Printer

Specification

Earth Continuity

  • Output Current – 200mA minimum into 2Ω
  • Test Voltage (o/c) – 9V DC nominal
  • Test Duration (Class I Test) – 2s nominal
  • Display Range – 0.01Ω to 19.99Ω
  • Pass Value (Class I Test) – 0.2Ω

Insulation Resistance

  • Test Voltage – 250/500V DC @1mA nominal, <2mA (s/c)
  • Test Duration (Class I or II) – 2s
  • Display Range – 0.01MΩ to 19.99MΩ
  • Pass Value – Class I: 1.0MΩ, Class II: 2.0MΩ

Equivalent Leakage

  • Test Voltage – 40V Nominal AC 50Hz Open Circuit
  • Test Duration – 2s
  • Display Range – 0.1mA to 19.99mA
  • Pass Value – 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II

IEC Lead Test

  • Test Voltage – 5V DC Nominal
  • Test Duration – Time for Test (2s max)
  • Test – Live/Neutral Checks for o/c, s/c and crossed

Protective Conductor Current

  • Test Voltage – Supply voltage, max current 13A
  • Test Duration – 120s Maximum
  • Display Range – 0.15mA to 9.99mA
  • Pass Value – 0.75mA/3.5mA (user selectable with 0.75mA as default)

Touch Current

  • Test Voltage – Supply voltage, max current 13A
  • Test Duration – 120s maximum
  • Display Range – 0.10mA to 3.50mA
  • Pass Value – 0.25mA

3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory

  • Test Voltage – 3 phase supply voltage
  • Test Duration – Continuous measurements
  • Display Range – 0.10mA to 9.99mA
  • Pass Value – 0.75mA/3.5mA (user selectable with 0.75mA as default)

RCD Trip Time

  • Test Voltage – Mains supply voltage
  • Test Current – 30mA/150mA rms sinusoidal
  • Test Current Phase – 0/180° auto switched on alternate tests
  • Measuring Range – 0ms to 500ms
  • Pass Value – 200ms

Power Socket Check

  • Input Voltage Range – 225-254V AC max current 13A UK
  •  Indicates configuration of voltage potentiall – Line to earth, line to neutral, neutral to earth

General

  • Memory Size – 999 Test Records
  • Power Source – 6 x AA Batteries

Supplied Accessories

The Seaward Primetest 250+ comes with:

  • Seaward 0.5m extension lead adaptor
  • Seaward Earth Lead with probe and clip
  • Seaward Mains Lead
  • 6 x AA Batteries
  • USB Download Lead
  • Seaward Carry Case
  • Seaward Operating Instructions