Description

The Seaward Primetest 50 PAC Checker is a portable, battery-powered instrument designed for low-volume testing duties in domestic and commercial environments. It is capable of testing Class I and Class II appliances and extension leads at the push of a button.

The Seaward Primetest 50 tests earth bond continuity, insulation and leakage current to pre-set pass and fail limits before providing a PASS/FAIL indication. As no actual readings are provided, the checker is unsuitable for testing long extension leads.

Additionally, the user can download the Seaward PATMobile App for free to an iOS or Android device and this can be used to store results in an organised database alongside pictures from the devices camera. It is also possible to export reports from the app.

The Seaward Primetest 50 is suitable for a various items of office equipment such as PCs, printers, fax machines and kitchen equipment, and is ideal for novice testing operatives thanks to its simplicity and portability.

Key Features

  • Provides PASS/FAIL indication
  • Portable, handheld design
  • Battery-powered
  • Tests Class I, Class II and IEC leads

 

Primetest 50 Primetest 100 Primetest 250 Primetest 250 Plus
Earth Continuity Test
Insulation Test (250V)
Insulation Test (500V)
Polarity Test
Leakage Current Test
Touch Current Test
Protective Conductor Current Test
RCD Trip Time Test
PASS/FAIL Indication
Numeric Reading Values
Extension Lead Test
Socket Test
Three-Phase Testing
Auto Test Sequences
Internal Memory (999 results)
Compatible with Seaward TNT Pro Printer

Specification

Earth Continuity

  • Test Current: +/- 200mA DC
  • PASS/FAIL Threshold: 0.2ohms

Insulation Resistance

  • Test Voltages: 500V DC
  • PASS/FAIL Threshold: 2Mohms

IEC Lead Test (cord)

  • Earth Continuity, Insulation Resistance. Live, Neutral Continuity and Polarity

Power Socket Test

  • Input Voltage range 230V +10%, -15% AC
  • Indicators: Phase to Earth Voltage, Phase to Neutral Voltage and Neutral to Earth

Dimensions

  • 260 x 100mm x 55mm

Weight

  • 800g

Supplied Accessories

The Seaward Primetest 50 comes with:

  • 230V Extension Lead Adaptor
  • Test lead with crocodile clip
  • Instruction Manual
  • 12 Month Warranty
  • 6 x AA Batteries
  • Carry Case